Required Programming
Application Diagram
HVAC Temperature Control - Mechanical Thermostat
Location Value Function
9940 01 Zone type = 011, Option 1 = 064, Option 2 = 001,
Hardware device = 022, Input = 01
4097 001 Enable control channel 1
4119 009 Auxiliary output 9
4865 001 Enable control channel 33
4887 010 Auxiliary output 10
0194 001 System trigger – arm to away
4064 006 System trigger options
0901 009 Zone – control channel link option (open = on, close = off)
0902 033 Zone – control channel link channel (zone 1, channel 33)
6657 117 Enable sensor, speak temperature with time, high and low limits,
hysteresis = 2 degrees
6659 085 High limit temperature (programmable)
6660 065 Low limit temperature (programmable)
0135 005 Speak remote control menu, speak temperature when time is requested
07/99